X50

china

Anesthetic Workstation

  • Suitable: Neonatal, Adults and pediatric.
  • 1” TFT color screen with touch screen.
  • Friendly user interface.
  • With knob and key input.
  • Tidal volume setting: 20 ~1500 ml (optional 10-1600 ml).
  • Sufficient modes of ventilation: VCV, PCV, SIMV-VC, SIMV-PC, PSV, Backup, Manual.
  • Gas supply: O2, N2O, Air.

Optional:                             

*PRVC, SIMV-PRVC, O2, ETCO2, AGSS and Suction.

Good integration:

  • Built-in active expiratory PEEP valve.
  • Built-in battery.
  • Lung mechanics parameters and loop (P-V, V-F).
  • Electronic flow meter more accurate and stable, auxiliary flow meter, gas system, hypoxic guard system, O2 flush.
  • Vaporizer mount: selectatec bar support 2 vaporizers, ACGO, 2 Yokes (O2 & N2O).

Ergonomics design anesthesia machine:

  • More convenient operating and display system for clinical operations requirements; suitable for a wide range of anesthesia applications: adult infant, tidal volume: 20 ~ 1500 mL (optional 10 ~ 1600mL).
  • Electronic PEEP, imported proportional valve, High precision electronic flow meter, all ensure the excellent performance, durable, long-term use.
  • Highly integrated circuits, centralized heating technique avoids condensation in the circuit with bypass function, the canister can be replace during ventilation without stopping anesthesia operation.
  • Sufficient monitoring parameter: Ppeak, Pmean, Pplat, Pmin, PEEP Compliance, Resistance, O2 %, EtCO2, FiCO2.
  • Clincian’s health concerns: independent AGSS systems avoids anesthesia gas commulation & removes health concerns for clinicals.
  • Complete alarm function to make sure that operating is accurate & stable.

Technology innovation:

  • A closed and semi-closed circuit, natural latex free to avoid allergic reaction. Fully 134 ° C autoclavable to avoid cross infection, especially for respiratory disease operation.
  • Embedded design, flow sensor with variable orifice, suitable for different applications from infant to adult, Tidal volume 20 ~ 1500 mL (optional 10 ~ 1600 mL).
  • Efficient, integrated heating system, optimized airway and water trap design to ensure the air flow without effected by condensation, also ensures the accuracy of operation for long term.
  • Bypass design, fast and convenient replacement of absorber canister, priority alarm function reminds the user always for safe and reliable operation.

Humanized design:

  • Circuit heating system controls the temperature at 35 (±2° C) to avoid condensation effect on the flow sensor lifetime and accuracy; also make the patient feel more comfortable.
Bypass design enable fast and convenient replacement of CO2 canister without stopping operation. Special designed chamber assembly monitoring to avoid disoperation.