ECG-6S

TRIUP

ECG-6S

 Technical parameters:

1.    Normal work environment

Operation:

-         Environment temperature: +5 c - +35 c

-         Relative humidity: ≤ 80%

-         Power supply: AC: 100V-240V, 50/60 Hz

          DC: 7.4 V, 3700mAh rechargeable lithium battery

-         Atmospheric pressure: 86kPa-106kPa

2.  Store and transportation

-         Environment temperature: -40c - -55c

-         Relative humidity: ≤95%

-         Atmospheric pressure: 50kPa – 106kPa

3.    Input way: floating and defibrillation protection

4.    Lead standard 12 lead

5.    Patient leak current: <10µA

6.    Input impedance: ≥ 50MΩ

7.    Frequency response: 0.05Hz – 150Hz ( - 3dB - + 0.4dB)

8.    Time constant: time constant ≥ 3.2s

9.    CMRR: >60Db , >100Db (Add filter)

10.   EMG filter: 25 Hz/35Hz ( -3Db)

11.    AC filter: 50Hz/60Hz (≥20Db)

12.    Recording way: thermal printing system

13.    Specification of recording paper: 110 mm (W)*20m(L) high-speed thermal paper

14.    Paper speed:

Auto-record: 5mm/s, 6.24mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, 100mm/s, error: ±5%

Rhythm record: : 5mm/s, 6.24mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, 100mm/s, error: ±5%

Manual-record: : 5mm/s, 6.24mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, 100mm/s, error: ±5%

Sensitivity choice: 2.5/5/10/20/40mm/Mv, error: ±5%

15.Auto-record: record following the record format and auto-mode, auto leads-changing, auto measurement and analysis.

16.Rhythm record: record following the rhythm format and rhythm mode, auto measurement and analysis.

17.Manual record: record following the record, manual leads-changing

18 Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-T interval, Q-Te. P Axis, T Axis, R (V5), S (V1), R(V5)+ S(V1)

19.Enduring polarization voltage: ±500Mv

20 Sampling precision: 12bits

  Sampling rate: 1000Hz

22.Noise level: ≤ 15µVp-p

Accessories:

Sell in standard

User manual 1 set

Lead cable 1 set

Limb electrode clamp 1 set

Chest electrode 1 set

Wire group 1 set

Equipotential connecting wire 1 set

Thermal recording paper 1 set

Sell in addition

Synchro uploading line

 PHYSICAL IDENTITY:

Size 315L*215W*92H mm

Net weight: 1.7kg

ECG-6S six channel ECG is such a kind of electrocardiograph, which samples 12 leads ECG signals simultaneously and prints out the ECG waveforms with thermal printing system. Its functions are as follows: recording and displaying ECG waveforms in auto/manual mode: auto-measuring and auto-diagnosing the ECG wave parameters: prompting the state of lead off and paper lack, switching several kinds of interface languages, managing the case database.

FEATURES:

-         7” TFT color screen is 800*480, touch screen and function key control at the same time, more convenient and shortcut

-         It is high resolution thermal printer and thermal-array (8dots/mm), you should not adjust anything Frequency response is up to 150 Hz

-         The device can record real time clear and exact six channel ECG waveform and remark continually. The remark includes: lead sign, sensitivity, paper speed, filter state, etc.

-         Full digital filter for resisting baseline draft, AC and EMG interference.

-         Adjust the baseline automatically, optimize the print setting, and choose the rhythm leads.

-         Under automatic mode, just press the button once, it starts record procedure, which can enhance your work efficiency.

-         The power supply includes both AC/DC, this device included built-in lithium rechargeable battery, automatic protection circuit, and It will shut automatically if there is no operation for 5 minutes.

-         This instrument can record 190 pieces of ECG waveform and print 120 minutes continually                   under the best DC state.

-         This instrument can store more than 1000 pieces patient’s data, more convenient for data review and statistic

-         The figure of whole device is elegant and gliding.

-         Digital signal processor for effective inhibition of baseline drift, interference, and the like.

-         The instrument has function with regular auto-measurement of ECG waveform parameters, auto-analyze and auto-diagnostic, it will help to reduce doctor’s burden and improve working efficiency.

-         Sampling twelve leads ECG signal at the same time, analyzing2*6+1 (rhythm lead).

2*6, 3*4, 3*4+1 (rhythm lead). 4*3, 4*3+1(rhythm lead). 6*2, 6*2+1 (rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7 recording mode at the same time and reporting with multi-formats.